Desalting Columns
Disposable or reusable gel filtration chromatography columns for use in protein biology or DNA extraction and purification, for the fractional purification of proteins, nucleic acids, and other macromolecules from low molecular-weight buffer salts and reagents.
Desalting columns are special kinds of gel filtration (exclusion) chromatography columns suitable for the fractional purification of proteins, nucleic acids, and other macromolecules. Their use offers a more convenient and quicker alternative to dialysis.
Desalting columns may be disposable or reusable plastic or glass columns prepacked with beads of a suitable media, typically polysaccharide (Sephadex), or porous polyacrylamide that are more resistant to enzymatic degradation. The beads have defined molecular weight cut-off (MWCO) exclusion points (typically around 6000 Da) that trap, retain, and slow down the elution of small molecules below the MWCO, but exclude and therefore do not impede the more rapid elution of larger macromolecules such as proteins.
Desalting columns can achieve high sample recovery yields of >95%, with column capacities ranging from 5 μL to 10 mL that are suitable for applied sample volumes anywhere between 2 μL and 4 mL.
Types of Desalting Columns
• Columns designed for simple gravity flow
• Spin columns designed especially for centrifugation
• Pressure-compatible columns designed for use with suitable pumps or with integrated preparative LC systems
How Are Desalting Columns Used?
• Removal of salts from protein samples
• Buffer exchange prior to downstream electrophoresis or affinity chromatography
• Removal of unreacted radioactive labels
• Removing phenol or free nucleotides from nucleic acid preparations
• Removing of primers or dyes from PCR or sequencing reactions
• Removal of other low molecular weight compounds such as cross-linking, labelling or derivatization reagents, cofactors, inhibitors, or other contaminants
- (2)
- (3)
- (42)
- (6)
- (2)
- (3)
- (36)
- (1)
- (26)
- (2)
- (18)
- (5)
- (42)
- (1)
- (1)
- (4)
- (2)
- (4)
- (2)
- (2)
- (2)
- (2)
- (2)
- (2)
- (4)
- (4)
- (2)
- (4)
- (2)
- (2)
Filtered Search Results
Thermo Scientific™ Zeba™ Spin Desalting Columns and Plates, 40K MWCO, 75 μL–10 mL
The new and enhanced Zeba Spin and Micro Spin Desalting columns and plates are designed for efficient desalting and buffer exchanging proteins with a molecular weight >40 kDa and removing small molecules less than 2 kDa. They provide exceptional desalting and protein recovery performance.
| Disposable | Single-use |
|---|---|
| MWCO | 40 kDa |
| Column Type | Size-exclusion, Proprietary Resin |
| Purification Target | Buffer Exchange, Protein |
| Product Line | Zeba |
Thermo Scientific™ Zeba™ Spin Desalting Columns, Plates, and Cartridges, 7K MWCO, 0.5–100 mL
Perform high-throughput protein recovery (7K MWCO) and sample desalting for mass spectrometry, HPLC, capillary electrophoresis, metabolite screening, and assay development with ready-to-use Thermo Scientific Pierce Zeba desalting chromatography columns, plates, and cartridges.
| MWCO | 7.0 kDa |
|---|---|
| Column Type | Size-exclusion, Proprietary Resin |
| Purification Target | Buffer Exchange, Protein |
| Product Line | Zeba |
Cytiva HiTrap™ Desalting Prepacked Columns
For rapid convenient desalting and buffer exchange. HiTrap™ Desalting Prepacked Columns are prepacked, ready to use column for group separation between high and low molecular weight substances.
| Disposable | Reusable |
|---|---|
| Particle Size | >20 μm (dry), 15 to 88 μm (wet) |
| Content And Storage | 4°C to 30°C in 20% Ethanol |
| Diameter (English) Inner Column | 0.62 in. |
| Description | HiTrap Desalting are ready-to-use 5 mL columns prepacked with Sephadex G-25 Superfine resin for fast and convenient desalting and buffer exchange. |
| Volume (Metric) Bed | 5 mL |
| For Use With (Application) | For rapid convenient desalting and buffer exchange |
| Diameter (Metric) Inner Column | 16 mm |
Cytiva HiPrep™ 26/10 Desalting Columns
Provide reliable and reproducible desalting and buffer exchange with sample sizes of up to 15mL per column. Cytiva HiPrep 26/10 Desalting Column is a convenient, easy-to-use column prepacked 53mL column with Sephadex G-25 Fine for desalting and buffer exchange.
| Disposable | Reusable |
|---|---|
| Particle Size | >20 μm (dry), 17 to 132 μm (wet) |
| Content And Storage | 4°C to 30°C in 20% Ethanol |
| Diameter (English) Inner Column | 1.02 in. |
| Description | HiPrep 26/10 Desalting are convenient, easy-to-use, 53 mL columns prepacked with Sephadex G-25 Fine resin for desalting and buffer exchange. |
| Volume (Metric) Bed | 53 mL |
| For Use With (Equipment) | Laboratory pump or chromatography system such as AKTA design |
| Product Type | HiPrep 26/10 Desalting |
| Diameter (Metric) Inner Column | 26 mm |
Cytiva PD SpinTrap™ G-25 Desalting Columns
Use for convenient and fast small-scale cleanup of proteins and other large biomolecules (>5000 Mr). Cytiva Life Sciences™ PD SpinTrap™ G-25 Desalting Columns provide the option of running multiple samples in parallel.
Thermo Scientific™ Pierce™ Dextran Desalting Columns (5K MWCO)
Ready-to-use, gel-filtration Thermo Scientific Pierce Dextran Desalting Columns can separate proteins and macromolecules from low-molecular weight buffer salts and reagents up to 5000 Daltons (5 kDa) in 5- or 10-mL volumes.
| Disposable | Single-use |
|---|---|
| MWCO | 5.0 kDa |
| Content And Storage | Store at room temperature or 4°C. |
| Format | Gravity Flow Column |
| Product Type | Desalting Column |
| Column Type | Size-exclusion, Dextran Resin |
| Quantity | 5 Columns |
| Purification Target | Buffer Exchange, Protein |
| Product Line | Pierce |
Thermo Scientific™ Pierce™ Polyacrylamide Spin Desalting Columns, 7K MWCO, 0.7 mL
Separate proteins and other macromolecules from low-molecular weight buffer salts and reagents with Thermo Scientific Pierce 7K MWCO (molecular-weight cutoff) Polyacrylamide Spin Desalting Columns, which are porous polyacrylamide-based gel-filtration columns for biological sample preparation.
| MWCO | 7.0 kDa |
|---|---|
| Content And Storage | Upon receipt store at 4°C. |
| Format | Spin Column |
| Description | Pierce™ Polyacrylamide Spin Desalting Columns, 7K MWCO, 0.7 mL |
| Product Type | Spin Desalting Column |
| Column Type | Size-exclusion, Polyacrylamide Resin |
| Purification Target | Buffer Exchange, Protein |
| Sample Volume (Metric) | 30 to 120 μL |
| Product Line | Pierce |
Thermo Scientific™ Pierce™ Polyacrylamide Desalting Columns, 1.8K MWCO, 5 mL
Thermo Scientific Pierce 1.8K MWCO (molecular-weight cutoff) Polyacrylamide Desalting Columns are ready-to-use, disposable, gel-filtration columns for separating proteins and other macromolecules from low-molecular-weight buffer salts and reagents.
Sorbent Technologies Inc SorbaSep™ FPLC Desalting Columns, with Sorbadex S-25 Superfine for buffer exchange and/or desalting using a syringe, a pump, or a chromatography system. 5.0 ml, 5 columns
SorbaSep™ FPLC Desalting Columns - For desalting using FPLC and liquid chromatography systems (e.g. Cytiva AKTA™, Bio-Rad NGC™, and Knauer AZURA™). SorbaSep™ FPLC Columns are preloaded with SorbaDex™-25 Superfine, a beaded composite size-exclusion matrix. It exhibits high flow rates, excellent resolution, and chemical stability. The columns are used in a fractionation range for globular proteins from 1 and 5kD, aqueous compatible, pH range of 2-13.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Sigma Aldrich Fine Chemicals Biosciences HiTrapR Desalting Columns
HiTrap(R) Desalting is a ready-to-use 5 mL column prepacked with Sephadex(R) G-25 Superfine for fast and convenient desalting and buffer exchange.HiTrap(R) Desalting is a prepacked ready to use column for group separation between high and low molecular weight substances i.e. buffer exchange prior to or after different chromatographic steps removal of low molecular weight contaminants or removal of reagents to terminate a reaction.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp Sep-Pak SEC Desalting Cartridge, 1 cc, 5K MWCO, Start-Up Kit
The Sep-Pak SEC Desalting Cartridge 1cc Start-Up Kit is designed for efficient purification, desalting, and buffer exchange of proteins with a 5,000 molecular weight cut-off. This kit supports up to 96 samples through gravity-assisted flow in a 1cc syringe barrel configuration, compatible with both manual and automated laboratory workflows for clean-up prior to optical or MS detection.
- Desalts and buffer exchanges up to 96 samples.
- Syringe barrel configuration for gravity-assisted flow.
- Cartridge volume of 1 cc with 5,000 molecular weight cut-off.
- Compatible with manual and automated workflows.
- Ensures efficient clean-up for optical or mass spectrometry detection.
- Quality control tested for ≥ 80% protein recovery.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Waters Corp Sep-Pak SEC Desalting Cartridge, 1 cc, 5K MWCO, Classic Cartridge
This SEC desalting cartridge is designed for gravity-assisted flow, offering efficient purification, desalting, and buffer exchange for proteins with a molecular weight cut-off of 5,000. It can be used in both manual and automated workflows, providing efficient sample clean-up prior to optical or MS detection. Each cartridge is QC tested to ensure high protein recovery and reproducibility.
- Designed for gravity-assisted flow and efficient sample clean-up.
- Purifies, desalts, and performs buffer exchange for proteins with a molecular weight cut-off of 5,000.
- Compatible with manual and automated workflows.
- QC tested to ensure ≥ 80% protein recovery.
- Packing material is a crosslinked spherical dextran-based resin, stable from pH 2–13.
- Exclusion limit is ≥5 kDa for globular proteins and 20 base pairs for nucleic acids.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Epoch Life Science Inc EconoSpin® prepacked G25 Spin Columns with inert support for Dye Terminator Removal, Desalting, Pre-filtration etc. With screw cap and snap off end-tail (250 columns)
PP housing with prepacked G25 on an inert support. 700 ul bed volume. 50-200 ul sample volume. Liquid tight screw cap enables long term buffer storage and eliminates splash when opening/closing. Ideal for protein desalting or post-sequencingg cleanup for Sanger sequencingg. Ideal for small volume batch mode His-tag protein purification when used with Ni+ agarose. 250 columns.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Epoch Life Science Inc EconoSpin® prepacked G25 Spin Columns with inert support for Dye Terminator Removal, Desalting, Pre-filtration etc. With screw cap and snap off end-tail (50 columns)
PP housing with prepacked G25 on an inert support. 700 ul bed volume. 50-200 ul sample volume. Liquid tight screw cap enables long term buffer storage and eliminates splash when opening/closing. Ideal for protein desalting or post-sequencingg cleanup for Sanger sequencingg. Ideal for small volume batch mode His-tag protein purification when used with Ni+ agarose. 50 columns.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Thermo Scientific™ Zeba™ Spin Desalting Columns and Plates, 40K MWCO, 75 μL–10 mL
Effectively remove salt and other molecules (40K MWCO) from samples and attain excellent protein recovery with ready-to-use Thermo Scientific Pierce Zeba desalting chromatography columns and plates, which feature a proprietary size-exclusion chromatography resin.
| MWCO | 40 kDa |
|---|---|
| Column Type | Size-exclusion, Proprietary Resin |
| Purification Target | Buffer Exchange, Protein |
| Product Line | Zeba |