Syringeless and Syringe Filters
- (4)
- (147)
- (4)
- (96)
- (1)
- (262)
- (3)
- (9)
- (1)
- (6)
- (8)
- (1)
- (1)
- (1)
- (2)
- (2)
- (16)
- (3)
- (1)
- (4)
- (1)
- (8)
- (26)
- (13)
- (7)
- (12)
- (7)
- (5)
- (6)
- (6)
- (7)
- (4)
- (1)
- (13)
- (9)
- (157)
- (43)
- (1)
- (20)
- (22)
- (30)
- (58)
- (24)
- (4)
- (1)
- (2)
- (1)
- (3)
- (33)
- (4)
- (391)
- (74)
- (8)
- (369)
- (1)
- (18)
- (14)
- (110)
- (131)
Filtered Search Results
Cytiva Whatman™ Puradisc Nylon Syringe Filters: Nonsterile
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Caters to a wide variety of sample types and applications, including capillary electrophoresis, biological preparations, protein filtration, and UV spectroscopy sample preparation. Whatman™ Puradisc Nylon Syringe Filters: Nonsterile are resistant to a range of organic solvents and suitable for use with high pH samples.
| Type | Syringe Filter |
|---|---|
| Dimensions (L x W x H) | 22.9 x 28.4 mm |
| Outlet Style | Male Luer |
| Diameter (Metric) | 25 mm |
| Inlet Style | Female Luer Lock |
| Housing Material | Pigment Free Polypropylene (PP) |
| Material (Membrane) | Nylon |
| Volume (Metric) | Up to 100 mL |
| Pressure Rating | 5.2 bar (75 psi) |
| Filter Type | Syringe Filter |
| For Use With (Application) | For aqueous or solvent-based solutions, HPLC, TLC, GC sampling |
| Sterility | Non-sterile |
| Filtration Area | 4.2 cm2 |
Fisherbrand™ Syringe Filters: Nylon Membrane
Low hold-up volume helps you to recover virtually all of your sample after filtering
| Type | Syringe Filter |
|---|---|
| Material (Membrane) | Nylon |
| Sterility | Non-sterile |
Thermo Scientific™ Target2™ Nylon Syringe Filters
Ensure cleaner sample extracts by removing interfering materials and fine particles prior to injection with these robust nylon syringe filters. Ideal for general HPLC use.
| Disposable | Single-use |
|---|---|
| Type | Syringe Filter |
| Housing Material | Polypropylene |
| Material (Membrane) | Nylon |
| Quantity | 100/Pk. |
| Certifications/Compliance | Target Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. |
| For Use With (Application) | HPLC, SPE |
| Sterility | Non-sterile |
| Product Line | Target2 |
Choice™ Nylon Syringe Filters
Use Thermo Scientific™ Choice™ Nylon Syringe Filters as the economic option for most general laboratory filtration, and for filtration of most HPLC samples.
| Disposable | Single-use |
|---|---|
| Type | Syringe Filter |
| Housing Material | Solvent Resistent, Low-Extractable Polypropylene |
| Material (Membrane) | Nylon |
| Quantity | 100/Pk. |
| Pressure Rating | 90 psi |
| For Use With (Application) | HPLC, SPE |
| Prefilter | No |
| Sterility | Non-sterile |
| Product Line | Choice |
Basix™ Syringe Filters, Nylon, Sterile
Attach to the end of syringes and filter contents as it is being forced out. Fisherbrand™ Basix™ Syringe Filters, Nylon, Sterile offers high sample throughput.
| Diameter (Metric) | 25 mm |
|---|---|
| Housing Material | Acrylic |
| Material (Membrane) | Nylon |
| Sterility | Sterile |
Cytiva™ Acrodisc™ Syringe Filters with Nylon Membrane
A Pall Life Sciences product that provides excellent chemical compatibility with esters, bases, and alcohols. Saves time because no prewetting is required.
Fisherbrand™ Syringe Filters: PTFE Membrane
Low hold-up volume helps you to recover virtually all of your sample after filtering
| Type | Syringe Filter |
|---|---|
| Material | PTFE |
| For Use With (Application) | Ideal for degassing/clarifying aqueous and solvent samples |
Thermo Scientific™ Titan3™ Nylon Syringe Filters
Choose these filters for maximum confidence or for high-solids applications.
| Disposable | Single-use |
|---|---|
| Type | Syringe Filter |
| Housing Material | Polypropylene |
| Material (Membrane) | Nylon |
| Certifications/Compliance | Titan3 Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. |
| For Use With (Application) | Sample Filtration: general use, most HPLC samples |
| Sterility | Non-sterile |
| Product Line | Titan3 |
Fisherbrand™ Syringe Filters - Nonsterile, Durapore™ PVDF Membrane
Low hold-up volume helps you to recover virtually all of your sample after filtering
| Type | Syringe Filter |
|---|---|
| Diameter (Metric) | 33 mm |
| Sterility | Non-sterile |
Cytiva Whatman™ GD/X Nylon Syringe Filters
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Processes three to seven times more sample volume than filters without prefilter. Whatman™ GD/X Nylon Syringe Filters are specifically designed for filtration of viscous or otherwise hard-to-filter samples with high solids content.
| Disposable | Single-use |
|---|---|
| Dimensions (L x W x H) | 21.6 x 29.8 mm |
| Outlet Style | Male Luer |
| Inlet Style | Female Luer Lock |
| Material (Membrane) | Nylon |
| Volume (Metric) | ≤10 mL |
| Prefilter | GF/F |
Fisherbrand™ Syringe Filters - Nonsterile, Nylon Membrane
Low hold-up volume helps you to recover virtually all of your sample after filtering
MilliporeSigma™ Millex™-GP Sterile Syringe Filter Units with PES Membrane, 0.22 μm (Research Use Only)
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions.
| Pore Size | 0.22 μm |
|---|---|
| Disposable | Single-use |
| Temperature (English) Operating | 113°F |
| Housing Material | Hydrophilic PES |
| Material (Membrane) | PES |
| Color | Green |
| Volume (Metric) | <10 mL |
| Pressure Rating | 145 psi |
| For Use With (Application) | Sterilization of tissue culture media, protein solutions or aqueous solutions;Low Protein Binding |
| Sterility | Sterile |
| Type | Modified Acrylic Syringe Filter |
| Outlet Style | Male Luer Slip |
| Diameter (Metric) | 3.3 cm |
| Inlet Style | Female Luer Lock |
| Tip Material | Modified Acrylic |
| Temperature Range (English) | 113°F |
| Temperature Range (Metric) | 45°C |
| Temperature (Metric) Operating | 45°C |
| Autoclavable | Not Autoclavable |
| Hold up Volume (After Air Purge) | <100 μL |
MilliporeSigma™ Millex™ Sterile Syringe Filters: Durapore™ PVFD Membrane
Ready-to-use, syringe-driven units designed for sterilizing and clarifying sterile solutions are available in 0.1, 0.22, 0.45 and 5.0μm pore sizes
| Disposable | Single-use |
|---|---|
| Temperature (English) Operating | 113°F |
| Housing Material | PVDF |
| Material (Membrane) | PVDF (Hydrophilic) |
| Color | Yellow |
| Quantity | 50/Pk. |
| Pressure Rating | 145 psi |
| Sterility | Sterile |
| Type | Syringe Filter, Medical |
| Outlet Style | Male Luer Slip |
| Diameter (Metric) | 3.3 cm |
| Inlet Style | Female Luer Lock |
| Tip Material | Modified Acrylic |
| Temperature Range (English) | 113°F |
| Certifications/Compliance | Meets USP Class VI Biological tests for plastics. All 33 mm filters are CE-marked and suitable for both medical and laboratory applications outside the U.S. |
| Temperature Range (Metric) | 45°C |
| Temperature (Metric) Operating | 45°C |
| Autoclavable | Not Autoclavable |
| Hold up Volume (After Air Purge) | <100 μL |
Corning™ Nylon Syringe Filters
Greener Choice
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More
Recommended for applications requiring very low extractables because they do not contain any wetting agents, detergents or surfactants. Corning™ Nylon Syringe Filters provide excellent chemical resistance for optimum performance in filtering aggressive solutions.
| Type | Syringe Filter |
|---|---|
| Diameter (Metric) | 25 mm |
| Material (Membrane) | Nylon |
| Volume (Metric) | 0.5 to 100 mL |
| Tip Material | Polypropylene |
| Pressure Rating | 87psi |
| For Use With (Application) | For tissue culture and HPLC |
| Hold up Volume (After Air Purge) | 150 μL |
Basix™ Syringe Filters, Nylon, Non-Sterile
Attach to the end of syringes and filter contents as it is being forced out. Fisherbrand™ Basix™ Syringe Filters, Nylon, Non-Sterile offers high sample throughput.
| Housing Material | Polypropylene |
|---|---|
| Material (Membrane) | Nylon |
| Sterility | Non-sterile |